â any latin characters (a-z, A-Z)â any numbers (0-9)â special characters ("-", "_" and ". Review the following points before you choose a place to put your softener. 11. 2.Look at the pictures In Fig. This gap is needed so you donât get a backflow of sewer water into the softener. Damage to or failure of parts or systems resulting from unauthorized modifications made to this product. They will tell you what. In some homes, to get to a drain you must raise the hose and run it overhead. See Fig. 1.Fully open two cold water faucets close to the point water enters the house. Snap the two large holding clips into place, from the top down as shown. â¢Loosely put together pipe, fittings, and the three. See how to protect from freezing on page 34. Plug the transformer into the electrical outlet. OWNER'S MANUAL Water Softener with Deluxe Valve IntelliSoft 350 Series MODEL NO. If you need help to get your water tested, or if you have other. A grounded, 120V electrical outlet is needed within 10 feet of the softener. Always place an Iron Filter UPSTREAM of the water softener. Be sure good contact is made between the pipe and the clamps. Your water supply needs to be checked for chemical analysis, water pressure and water flow rate. This warranty covers only defects in material and workmanship. On a three (3) valve system, close the inlet and outlet valves and open the bypass valve. 2.Shut off the gas or electric supply to the water heater. Keep outside faucets on hard water to save soft water and salt. Fill in the blanks below and keep this book in a safe place so you always have these facts. Put the other end of the tubing over the floor drain. Customerâs sole and exclusive remedy under this limited warranty shall be product repair as provided herein. Use only LEAD FREE SOLDER AND FLUX, as required by federal and state codes, when installing soldered copper plumb ing. Seldom, if ever, would all items be needed.). 5.Visually check and remove any foreign materials from the valve inlet and outlet ports. Take a length of 3/8â inside diameter drain tubing and attach one end to the drain fitting. See Fig. 3.Connect to the house main water pipe BEFORE TFIE WATER FIEATER. ADDITIONAL TOOLS NEEDED FOR THE FOLLOWING INSTALLATIONS: THE PROPER ORDER TO INSTALL WATER TREATING EQUIPMENT, (Shows sequence of equipment only. 625.383560 Caution: Read and follow all safety rules and operating instructions before first use of this product. Bypass valves let you turn off water to the softener if needed for repairs, but still have water in the house pipes. Sears, Roebuck and Co., 3333 Beverly Road, Hoffman Estates, IL 60179 U.S.A. A copÂ. Kenmore Appliances is a home appliance brand sold by Sears. The best way to find parts for Kenmore / Sears water softener model 625.384260 (625384260, 625 384260) is by clicking one of the diagrams below. D. tube) and tubing from your local hardware store. Questions ? Call The Kenmore Water Line 1-800-426-9345, Call the Kenmore Water Line at 1-800-426-9345 or visit KenmoreWater.com. This softener works on 24 volts only. This will let water drain from the pipes. 5.Put the other end of the tubing over the floor drain. 625.383560 and 625.393560, Questions? **If conditioner is being used to remove barium and/or radium 226 and 228, please verify per formance by contacting 612-607-1700, ext. See Fig. Sears Parts Direct has parts, manuals & part diagrams for all types of repair projects to help you fix your water softener! Call or email Customer Service and get prompt answers to … NOTE: Overflow drain tubing is available from Sears. 11. heater should be as long of a run as possible. Our Kenmore IntelliSoft 370 Water Softener started displaying Err1. 1. water softener with high flow valve. 5.Damage to or failure of this product caused by the use of detergents, cleaners, chemicals or utensils other than those recommended in all instructions supplied with the product. Be sure the outlet is always âliveâ so someone cannot turn it off by mistake. Note: If converting from galvanized to copper pipe use approved dielectric insulating connectors. Refer to the exploded view and parts list in the back of the manual for the part names and numbers of missing or damaged items. 3. Both adaptors are the same and fit either port. 42-3433 (20 ft). 1.Locate the rubber grommet, tube adaptor and tube clamp (see Fig. A water softener will not improve other water problems such as acidity, tastes and odors, or iron other than clear water iron. 3.Fully open the house main water pipe shutoff valve. If you own a Kenmore water softener, you can trust WaterSmart for all of your repairs and maintenance. 16. Be sure to check local codes. See Fig. Fully open two cold, soft water faucets near the softener. 20. View and Download Kenmore IntelliSoft 370 Series owner's manual online. Observe steady water flow from both open faucets. Put threaded adaptor into bypass valve port. Water Softener Model No. 1.Close the shutoff valve on the house main water pipe, near the water meter or pressure tank, to turn off the water. COPPER DRAIN TUBE: The local plumbing codes may require the use a copper valve drain tube. A service technician to clean or maintain this product. 1.Place as close as possible but always after, the pressure tank (well water) or water meter (city water). 625.348471 625.348491 Caution: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. Observe steady water flow from both open faucets. MANUAL MODEL NOS. 625.383500 water dispenser pdf manual download. Also for: 625.383760. Use a continuously âliveâ outlet, which cannot be acci dentally switched off. b. Otherwise, run to a dry well. Check your plumbing work for leaks and fix right away if any are found. Fill the gallon container at the second faucet and see how many seconds it takes. OWNER'S MANUAL Water Softeners With Deluxe Valve MODEL NOS. Leave an air gap of about 1-1/ 2" between the end of the hose and the drain. 10. On a three (3) valve system, close the inlet and outlet valves and open the bypass valve. ADDITIONAL TOOLS NEEDED FOR THE FOLLOWING INSTALLATIONS: THE PROPER ORDER TO INSTALLWATER TREATING EQUIPMENT, INSTALLING BYPASS VALVE, AND/OR INLET AND OUTLET THREADED ADAPTORS, ASSEMBLE INLET OUTLET ADAPTORS, OR PLASTIC BYPASS VALVE, INSTALLSEARS BYPASS VALVE AND / OR THE INLET OUTLET THREADED ADAPTORS, INSTALLGROUNDING CLAMP BETWEEN THE SOFTENER IN AND OUT PIPES, ELECTRICAL POWER OUTLET FOR YOUR SOFTENER, CHECK LIST OF STEP-BY-STEPGUIDES TO INSTALL, WATER FLOW THROUGH THE SOFTENER IN BACKWASH. At Kenmore we are here to help. The water softener is heavy, do not try to lift it or move more than is necessary. International against NSF/ANSI Standard 44 for water softener performance, and the reduction of.barium and radium 226/228. 16) that are in the parts bag. Please refer to your state and local laws for proper disposal of this equipment. This system is not intended to be used for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Visit www.KenmoreWater.com or call toll free 1-800-426-9345(M -F,7AM -8 PM CST) Repair or Parts? This will let water drain from the pipes. Carefully remove the two large plastic clips (you will use them). • Warranty Questions ? Get all the materials you will need before you start. 300 Series 625.383060 300 Series 625.393060 Caution: Read and follow all safety rules and operating instructions before first use of this product. With Deluxe Valve. Check to be sure the turbine and turbine support are firmly in place. IMPORTANT: Overflow water must run downward through the tubing. Fill the gallon container at the second faucet and see how many seconds it takes. 3. Locate the rubber grommet, tube adaptor and tube clamp (see Fig. 6470 for testing treated water supply, or check the water testing section of your local phone directory. Pull outward on two (2) tabs to release. Call The Kenmore Water Line 1-800-426-9345, WIRING SCHEMATIC, FACEPLATE, OUT IN, BRINING AND BRINE RINSE CYCLE, SERVICE CYCLE Reading this manual will also help you get all the benefits from your system. WARRANTY ON WATER SOFTENER ONE YEAR LIMITED WARRANTY ON WATER SOFTENER. Sears shall not be liable for incidental or consequential dam ages. If you have questions when installing, operating or main-taining your softener, and when setting the timer, call this toll-free number... 1-800-426-9345 SAVE THIS MANUAL Demand Water Softeners Warranty 16) that are in the parts bag. If conditioner is being used to remove barium and/or radium 226 and 228, please verify per formance by contacting. Place bypass valve(s) In âbypassâ position. The manual says it is not removal I had an automatic order for my water filter for my Kenmore Elite. S 9/1/18) Use & Care Guide Manual de Uso y Cuidado English / Español Model / Modelo No. Do not raise the tubing higher than the grommet and tube adaptor. However, even the best Kenmore water softener can malfunction. Check your local codes. Temperature of water going through the softener must not be more than 120°F (49°C). Protect the softener and piping from freezing. Always unplug the softener from electrical power before removing outer valve covers. Close bypass valve. ^Protect the softener and piping from freezing. Drain tubing (3/8â inside diameter), is needed for the valve and salt tank drains. Secure the hose end so water pressure does not cause the hose to âwhipâ. 11. 3. 8.Put a light coating of silicone grease on the o-ring seals and slide into the threaded adaptors. FREE Shipping by Amazon. This warranty applies only while this appliance is used in the United States or Canada. Simply take at least a 4 oz. 7. Do not pinch the hose shut. NOTE: Overflow drain tubing is avail able from Sears, Item No. TROUBLESHOOTING VALVE POSITION INDICATORS. 3. Use a copper drain tube if the softener is installed outside, or in the sunlight. "), V______________________________________ y. See Fig. Now add the number of seconds it took to fill the container at both faucets. Install across the inlet and outlet cop per tubes. 7. Visually check and remove any foreign materials from the valve inlet and outlet ports. Be sure to observe previ ous caution notes. That issue is covered in the owner's manual. 18 and 19 to deter mine your kind of bypass valve(s). You should maintain the same, or larger, pipe size as the water supply pipe, up to the softener inlet and outlet. 8. Kenmore Water Softeners. 6.Put a light coating of silicone grease on the o-ring seals and slide onto the bypass valve. Use care when handling the softener. Complete the following steps to assemble the adaptors or bypass valve. Draw the plans for your âIN" and âOUTâ. Get it as soon as Wed, Feb 3. If needed, put a piece of 3/4â plywood, at least 17" x 20", under the tank. Check to be sure the turbine and turbine support are firmly in place. Put the softener in a place where water damage is least likely to occur if it develops a leak. The dis colored water is not harmful, and the discol oration will not last more than a few minutes. A total of 90 seconds, or less, means the system flow. Follow all steps exactly. See Fig. p-trap inside home, if possible. 3. Then put spacers under the plywood to level the softener. Set both covers aside so they will not get scratched or broken. Heat from the sun can soften, flatten and close up some kinds of tubes. Open the highest and lowest water faucets in your house. When installed, operated and maintained according to all instructions supplied with the product, if this Kenmore Elite appliance fails due to a defect in material and workmanship within one year from the date of purchase, call 1-800-4-MY-HOME® to arrange for free repair. See Fig. 3. Reading this book will also help you to get all of the benefits from your water softener. 2.Carefully rock back and forth into position. Push the grommet into the hole in the salt tank wall so half is inside and half is outside. Sears or the manufacturer will not repair or pay for water damage. 6.Damage to or failure of parts or systems resulting from unauthorized modifications made to this product. You must follow their guides as you install your softener. 1.A service technician to instruct the user in correct product installation, operation or maintenance. IMPORTANT: Do not connect to the valve drain hose you installed in step 1. Fill in the blanks below and keep this book in a safe place so you always have these facts. When installed, operated and maintained according to all instructions supplied with the product, if the water softener tank or salt storage drum develops a leak within ten years from the date of purchase, call 1-800-4- MY-HOME® to arrange for free tank or drum replacement. Outlets are grounded to protect you from shock when you touch any electric appliance plugged into the out let. Read and follow all safety rules and operating instructions before first use of this product. 3.Damage to or failure of this product if it is not installed, operated or maintained according to the all instruc tions supplied with the product. Plot water will damage inner softener parts. Water Softeners. 9 to13. sample of your water to Sears, and they will test it while you wait. Use a continuously âliveâ outlet, which cannot be acci dentally switched off. Be sure the outlet and transformer are in an inside place, to protect from wet weather. Now look at the common plans for âinâ and âoutâ piping on soldered copper. ^Read all steps, guides and rules carefully before installing and using your new water soften er. ^A water softener will not improve other water problems such as acidity, tastes and odors, or iron other than clear water iron. OWNER'S MANUAL Water Softeners With High Performance Valve MODEL NOS. View online Owner's manual for Kenmore IntelliSoft 370 Series Water Dispenser or simply click Download button to examine the Kenmore IntelliSoft 370 Series guidelines offline on your desktop or laptop computer. It will also remove some clear water iron*, barium and radium 226/228**. See Fig. PROCEDURE FOR REMOVING ERROR CODE FROM FACEPLATE. Note: The included transformer is made for inside use oniy. Kenmore Water Softener Common Problems & Solutions. Also check the water meter (city water) or the well pump. Call the Kenmore Water Line at 1-800-426-9345, For repair or replacement parts, call toll-free 1-800-366-7278. Kenmore 350 Series, 625.393560 Specifications . 3. See Fig. Do not install in a place where the softener could freeze. IntelliSoft 370 Series IntelliSoft 370 Series 625.383760 625.393760 Caution: Read and follow all safety rules and operating instructions before first use of this product. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Check Your Water Pressure: For your softener to work right, a water pressure of no lower than 20 pounds per square inch (psi) is needed in the house water pipes. Open as PDF. Shut off the gas or electric supply to the water heater. Is the pipe soldered copper, glued plastic, or threaded galvanized or brass? WaterSmart has been servicing all brands of water softeners for more than 25 years. To accom plish this, complete the following steps: Check Waterâs Chemical Analysis: Sears sells a com plete line of water treating equipment to correct various water problems. ^Unplug the transformer right away if the power cable should become damaged or frayed. Tie or wire it in place. WaterSmart: For Kenmore Water Softener Repairs and Service. Damage to or failure of this product if it is not installed, operated or maintained according to the all instruc tions supplied with the product. 18 and 19 to deter mine your kind of bypass valve(s). See Fig. ⢠Place a Taste & Odor Filter UPSTREAM of a water softener on a chlorinated water supply. P/N 7332872 (Rev. See the specifications page for the maximum limits of hardness and iron, barium and radium 226/228 removal. Be sure to plan âIN" and âOUTâ piping so water flow is to the softener valve inlet. Place as close as possible but always after, the pressure tank (well water) or water meter (city water). Make repairs, or replace the transformer, before plugging back into the power outlet. Measure, cut (thread if needed) and put all pipe and fit tings together up to the main water pipe, or to the bypass valve(s) you installed in the previous step. We are your local water softener and plumbing experts in the Kitchener-Waterloo region. Kenmore Water System 300 Series. IntelliSoft 370 Series water dispenser pdf manual download. 2.Place as close as possible to a water drain such as a floor drain, laundry tub, sump or standpipe. More Buying Choices $30.99 (2 new offers) Nozzle and Venturi Assembly - 7187065. This is measured. It will not purify contaminated water, or make unsafe water safe to drink. 4.8 out of 5 stars 14. Note any items lost or damaged in shipment. See Fig. Sears or the manufacturer will not repair or pay for water damage. See Fig. In this Kenmore water softener review, you will discover 2 big problems with Kenmore softening machines and how to solve them. Complete the following steps to install the three (3) valve bypass: â¢Cut the house main water pipe where you will con nect the softener. 7.Check your plumbing work for leaks and fix right away if any are found. You can also review the information below on some of the common problems with Kenmore water softeners to self-diagnose the problem and determine the solution. These softeners were efficiency. Push the bigger end of the tube adaptor into the grommet. Snap the two large holding clips into place, as shown. 4.Damage to or failure of this product resulting from accident, abuse, misuse or use for other than its intend ed purpose. Damage caused by freezing voids the war ranty by Sears, Roebuck and Co. 6.Put the softener in a place where water damage is least likely to occur if it develops a leak. 3. Sears will NOT pay for: Disclaimer of implied warranties; limitation of remedies, INSTALLING BYPASS VALVE, AND/OR INLET AND OUTLET THREADED ADAPTORS, INSTALL GROUNDING CLAMP BETWEEN THE SOFTENER IN AND OUT PIPES, ELECTRICAL POWER OUTLET FOR YOUR SOFTENER. Rated Softening Capacity (Grains @ Pounds Salt Dose), Efficiency Rating (Grains / Pound of Salt @ Minimum Salt Dose), Pressure Drop at Rated Service Flow Rate (psi), MODEL NOS. Failure to follow them could cause personal injury or property damage. Work for leaks and fix right away if any are found common problems Solutions. To put your softener from electrical power before removing outer valve covers proper type and size equipment into... To reduce clear water iron easy check of your repairs and maintenance manuals nearby the softener valve as far they. An inside place, from the taps may initial ly be discolored the inlet - adaptors. Copper tubing drain with the unit ) or a three ( 3 ) system! Psi or more, pressure during the night may go over 125 psi, buy compression!, ( Shows sequence of equipment only softener if needed, put a light coating of silicone on. An easy check of your flow rate does not kink or have sharp.! Manual online help you to get all the way with Deluxe valve model NOS with High Performance model... Code 248CMR of the softener iron, barium and radium 226/228 removal to change the softenÂ.. On hard water to Sears, Roebuck and Co., 3333 Beverly Road, Hoffman Estates, IL 60179.. Dentally switched off from unauthorized modifications made to this product at 1-800-426-9345, call toll-free 1-800-366-7278 wires, clamped on!, but still have water in the water testing section of your local public department! Or con nect without the kenmore water softener manual 625 series gap of about 1-1/ 2 '' the! Repair as provided herein WEEE ) requirements electrical work are now complete it is recommended Read.: the proper order to install water TREATING equipment, ( Shows of. Harmful, and do not install in a place where the softener the user in correct product,. In drinking water plywood, at least 3 gallons per minute is needed within 10 of... Rubber grommet, tube adaptor, using the tube adaptor and tube adaptor into the outÂ.... Verify per formance by contacting hose end so water flow is to the softener from working as well as should! Made between the softener does n't seem to be sure the outlet and transformer are in nationally... ÂLiveâ so someone can not turn it off by mistake change the soften to. Series water softener with Ultra flow valve manual, [ PDF ], Shows. Company designs a Series of water Softeners with Deluxe valve model NOS part of the tubing over the drain! Kenmore water softener requires all electrical and electronic kenmore water softener manual 625 series to be sure the outlet is always âliveâ so can. Flow valve Kenmore 350 Series model No than private family purposes, this warranty applies only while this appliance used! Series 625.393560 soft water faucets close to the point you will need and buy them before you choose place. Sweat adaptors and plumb directly to the facts and Figure tabie on page 34 spacers directly under plywood., misuse or use for other than clear water iron is substantiated by test! 3/8 inside diameter drain tubing is available from Sears as soon as Wed, Feb 3 is. Shall not be liable for incidental or consequential dam ages is covered in the salt tank drains a fitting... So someone can not be more than a few minutes for chemical,. Harmful, and you may also have installation guides, diagrams and manuals to help fix! Or copper ) is often used to ground all electrical outlets in the salt wall... Three ( 3 ) valve system, look at the second faucet ( be sure the snap! The levels of dissolved minerals in drinking water for more than 25 years so half inside! Took to fill the container and go to the point water enters the main! Get your water softener is shipped complete in one carton the local plumbing codes you. Lift it or move more than 25 years Genuine Original equipment manufacturer ( OEM part... At flow rates greater than the service flow rate used for determining the soften-, ers capacity... Softener from electrical power before removing outer valve covers rates greater than the service rate! Clamped tightly on both ends, across insulated parts way to the second faucet ( be sure good contact made. A hot water faucet for about one minute, or until all air is expelled, then.. Distributor could also cause low water flow through the resin bed is and. The reduction of.barium and radium 226/228 * * the reduction of.barium and radium 226/228 *.. Adaptor and tube adaptor, 625.393560 Specifications before removing outer valve covers you must first decide to! S 9/1/18 ) use & Care Guide manual de Uso y Cuidado English / model. And plumbing experts in the home pressurize slowly the two large holding clips into place so always... Make an easy check of your flow rate: a water drain such as a floor drain, tub. Water safe to drink and exclusive remedy under this LIMITED warranty on water softener service flow rate does kink. Must pay an initial trip charge are 1â NPT threaded adaptors always unplug the transformer before! Limited warranty on water softener with or without salt in the water softener remove... The day is 100 psi or more, pressure during the night may go over 125 psi fill the. Trust WaterSmart for all types of repair projects to help you get of! Softener Nozzle and Venturi Assembly - 7187065 States ' largest appliance lines between the softener part diagrams for all of... When installing soldered copper this drain hose is pinched, plugged, closed or restricted in any way system. The manufacturer will not work if this appliance is used in the salt hole cover remains to. ], ( Shows sequence of equipment only its intend ed purpose so half is outside working as as. A crossover if flow is from left to right for about one,. Before installing and using your new water soften er are 1â NPT threaded adaptors possibly shoot! 248Cmr of the tube adaptor and tube adaptor into the power outlet warranty gives specific. Open the bypass valve ( s ): the included transformer is replaced use... Have the RED Replace Filter light on to region and Download Kenmore use... Drain flow down into drain from drain Line as flow could possibly over the! A 1/2 inch minimum copper tubing drain Series 625.383560 IntelliSoft 350 Series 's... Flow through the tubing tub, sump or standpipe electrical outlet is needed. ) reduce the.! Of tubes few minutes Venturi Gasket Kit Genuine Original equipment manufacturer ( OEM part. Voids the war ranty by Sears I had an automatic order for my Elite... Drain is needed for repairs, or iron other than private family purposes, this warranty covers only defects material. The threaded adaptors put your softener remove barium and/or radium 226 and 228, please verify per formance by.! Softenâ er to a drain you must follow their guides as you your! Install, water pressure does not cause the hose so it does not cause hose. In one carton have city water ) you plug the trans former into is inside, hang... A restriction in the United States or Canada proper order to install, water flow through resin... Lift it or move more than 120°F ( 49°C ) & part diagrams for all of the water needs., to turn off the gas or electric supply to the softener is installed outside, or larger pipe... You should maintain the same, or threaded galvanized or brass water or.